- Home
-
Products
- Cryogenics
- EIT - Electrical Impedance Tomography
-
Electrochemistry
- Potentiostats & Galvanostats
-
Electrodes (working, Reference, Counter and pH)
- Working Electrode
- Counter electrodes
- Reference electrode
-
pH Electrodes
- pH electrode for soil sample
- pH electrode for aquariums
- pH electrode for seawater
- pH electrode for potable water
- pH electrode for ultrapure water
- pH electrode for low ionic activity
- pH electrode for meat
- pH electrode for beer
- pH electrode for glue
- pH electrode for colorings
- pH electrode for cosmetic
- pH electrode for leather
- pH electrode for creams
- pH electrode for detergent
- pH electrode for effluent
- pH electrode for galvanic effluent
- pH electrode for school and universities
- pH electrode for clinical laboratories
- pH electrode for laboratory in general
- pH electrode for pharmaceutical laboratories
- pH electrode for milk and dairy
- pH electrode for waterfull media
- pH electrode for honey
- pH electrode for micro volumes
- pH electrode for paper
- pH electrode for proteins
- pH electrode for redox
- pH electrode for cheese
- pH electrode for liquid soap
- pH electrode for solids
- pH electrode for semisolid
- pH electrode for alcoholic solutions
- pH electrode for visual and dense solutions
- pH electrode for inorganic solvents
- pH electrode for organic solvents
- pH electrode for fruit juice
- pH electrode for vegetable juice
- pH electrode for sulfates
- pH electrode for flat surfaces
- pH electrode for textile
- pH electrode for paintes
- pH electrode for titration
- pH electrode for wines
- RRDE / Polishing kit / Spectroeletrochemistry
- Voltametric cells & Flow cells
- Lithography / Glass substrate electrode
- Corrosion tests
- FANN Instruments
- Impedance Analysers
- NIR
-
Tech Notes Eletrochemistry
- Basis of Potentiostat
- Basis of Working electrode
- Variety, Features and Shapes of Working electrodes
- Reference electrode
- Counter Electrode
- Hydrodynamic Voltammetry
- IDA electrode
- Cyclic Voltammetric Stripping (CVS)
- How to polish the Working electrodes
- Experimental data on RHE Reversible hydrogen elect
- Capillary Electrophoresis
- Microchip Electrophoresis
- Chromatography
- Cleaning and Maintenance Procedure of pH electrode
- Calibration Procedure pH ORP CONDUCTIVITY
- HOW TO POLISH THE DRE-PTR PT RING ASSEMBLY?
- Fuel cell Glossary
- Electrochemical Glossary
- Movies Library
- ELECTROCHEMICAL GLOSSARY
- Publications
- Allum News
-
- +14073604114
- [email protected]
- Home
-
Products
- Cryogenics
- EIT - Electrical Impedance Tomography
-
Electrochemistry
- Potentiostats & Galvanostats
-
Electrodes (working, Reference, Counter and pH)
- Working Electrode
- Counter electrodes
- Reference electrode
-
pH Electrodes
- pH electrode for soil sample
- pH electrode for aquariums
- pH electrode for seawater
- pH electrode for potable water
- pH electrode for ultrapure water
- pH electrode for low ionic activity
- pH electrode for meat
- pH electrode for beer
- pH electrode for glue
- pH electrode for colorings
- pH electrode for cosmetic
- pH electrode for leather
- pH electrode for creams
- pH electrode for detergent
- pH electrode for effluent
- pH electrode for galvanic effluent
- pH electrode for school and universities
- pH electrode for clinical laboratories
- pH electrode for laboratory in general
- pH electrode for pharmaceutical laboratories
- pH electrode for milk and dairy
- pH electrode for waterfull media
- pH electrode for honey
- pH electrode for micro volumes
- pH electrode for paper
- pH electrode for proteins
- pH electrode for redox
- pH electrode for cheese
- pH electrode for liquid soap
- pH electrode for solids
- pH electrode for semisolid
- pH electrode for alcoholic solutions
- pH electrode for visual and dense solutions
- pH electrode for inorganic solvents
- pH electrode for organic solvents
- pH electrode for fruit juice
- pH electrode for vegetable juice
- pH electrode for sulfates
- pH electrode for flat surfaces
- pH electrode for textile
- pH electrode for paintes
- pH electrode for titration
- pH electrode for wines
- RRDE / Polishing kit / Spectroeletrochemistry
- Voltametric cells & Flow cells
- Lithography / Glass substrate electrode
- Corrosion tests
- FANN Instruments
- Impedance Analysers
- NIR
-
Tech Notes Eletrochemistry
- Basis of Potentiostat
- Basis of Working electrode
- Variety, Features and Shapes of Working electrodes
- Reference electrode
- Counter Electrode
- Hydrodynamic Voltammetry
- IDA electrode
- Cyclic Voltammetric Stripping (CVS)
- How to polish the Working electrodes
- Experimental data on RHE Reversible hydrogen elect
- Capillary Electrophoresis
- Microchip Electrophoresis
- Chromatography
- Cleaning and Maintenance Procedure of pH electrode
- Calibration Procedure pH ORP CONDUCTIVITY
- HOW TO POLISH THE DRE-PTR PT RING ASSEMBLY?
- Fuel cell Glossary
- Electrochemical Glossary
- Movies Library
- ELECTROCHEMICAL GLOSSARY
- Publications
- Allum News
- Home
- > Electrochemistry
- > Electrodes (working, Reference, Counter and pH)
- > pH Electrodes
- > LabSen 553 Professional 3-in-1 pH/Temp. Electrode for Direct Soil pH Testing (AI3113)
LabSen 553 Professional 3-in-1 pH/Temp. Electrode for Direct Soil pH Testing (AI3113)
0% OFF
AI3113 LabSen 553 Professional 3-in-1 pH/Temp. Electrode for Direct Soil pH Testing, BNC Connector, POM
Description
- Proprietary ph sensor technology and materials from Switzerland
- Special LabSen Spear pH sensor tip, ideal for direct soil pH testing. No more slurry making.
- Pom housing, ideal for use in harsh environments
- Polymer electrolyte - not more clogged junction
- Long-life reference system, improving the stability of reference electrode and prolong the service life of the electrode
Backed by proprietary Swiss sensor technology and materials, the LabSen 553 3-in-1 pH/Temp. Spear Electrode/Sensor/Tester is designed for testing soil directly. (This is a replacement probe for Apera SX811-SL Meter) Long-Life Reference System – The LabSen 553 pH electrode adopts a long-life reference system, which is composed of a glass tube, AgCl and a reference silver wire. The top end of the slim glass tube is stuffed with cotton, which prevents the reaction between AgCl and electrolyte when temperature changes. It improves the stability of reference electrode and prolong the service life of the electrode. Polymer Electrolyte – The solid polymer electrolyte makes the electrode hard to be contaminated and maintenance-free. Special Glass Membrane – The LabSen 553 pH electrode adopts a spear sensor tip, which is ideal for directly testing semi-solid samples like soil. Compatible Apera Instruments' meters: PH700, SX823-B, MP511, PH800, PC800. May NOT work with other brands' meters because the temperature unit might be incompatible. The electrode is backed up with a 6-month warranty by Apera Instruments.
Applications
- Soil
Specifications
Code |
AI3113 |
|
Housing Material |
POM |
|
Temp. Sensor |
NTC 30kΩ |
|
Junction |
Ceramic+Single Pore |
|
Reference |
Long-Life |
|
Electrolyte |
Polymer |
|
Length |
90 mm |
|
Diameter |
15-6 mm |
|
Membrane Shape |
Spear |
|
Range |
0-14 pH |
|
Temp. Range |
0 to 60˚C (32 to 140˚F) |
|
Connector |
BNC / RCA |
|
Cable |
3 ft |