- Home
-
Productos
- Cryogenics
- EIT - Electrical Impedance Tomography
-
Electrochemistry
- Potentiostats & Galvanostats
-
Electrodes ( working, Reference, Counter )
- Working Electrode
- Counter electrodes
- Reference electrode
-
pH Electrodes
- pH electrode for soil sample
- pH electrode for aquariums
- pH electrode for seawater
- pH electrode for potable water
- pH electrode for ultrapure water
- pH electrode for low ionic activity
- pH electrode for meat
- pH electrode for beer
- pH electrode for glue
- pH electrode for colorings
- pH electrode for cosmetic
- pH electrode for leather
- pH electrode for creams
- pH electrode for detergent
- pH electrode for effluent
- pH electrode for galvanic effluent
- pH electrode for school and universities
- pH electrode for clinical laboratories
- pH electrode for laboratory in general
- pH electrode for pharmaceutical laboratories
- pH electrode for milk and dairy
- pH electrode for waterfull media
- pH electrode for honey
- pH electrode for micro volumes
- pH electrode for paper
- pH electrode for proteins
- pH electrode for redox
- pH electrode for cheese
- pH electrode for liquid soap
- pH electrode for solids
- pH electrode for semisolid
- pH electrode for alcoholic solutions
- pH electrode for visual and dense solutions
- pH electrode for inorganic solvents
- pH electrode for organic solvents
- pH electrode for fruit juice
- pH electrode for vegetable juice
- pH electrode for sulfates
- pH electrode for flat surfaces
- pH electrode for textile
- pH electrode for paintes
- pH electrode for titration
- pH electrode for wines
- RRDE / Polishing kit / Spectroeletrochemistry
- Voltametric cells & Flow cells
- Lithography / Glass substrate electrode
- Corrosion tests
- FANN Instrument ( ship only to Brazil )
- Impedance Analysers
- NIR
- CO2 & CH4 & Biogas and Hydrogen
-
Notas Técnicas em Eletroquímica
- Base del potenciostato
- Base del electrodo de trabajo
- Variedad, características y formas de los electrod
- Electrodo de referencia
- Contraelectrodo
- Voltametría hidrodinámica
- IDA electrodo
- Decapado Voltimétrico Cíclico (CVS)
- Cómo pulir la superficie de los electrodos de trab
- Datos experimentales del electrodo de hidrógeno re
- Electroforesis capilar
- Microchip de Electroforesis
- Cromatografía
- Procedimiento de limpieza y mantenimiento de eelec
- Procedimiento de calibración pH, ORP Condutividad
- ¿CÓMO PULIR EL CONJUNTO DE ANILLO PT DRE-PTR?
- Fuel cell Glossary
- Electrochemical Glossary
- Biblioteca de peliculas
- GLOSSÁRIO ELETROQUÍMICO
- Publications
- Allum News
- Technology of ACLN Nitrogen Liquefier
- Home
-
Productos
- Cryogenics
- EIT - Electrical Impedance Tomography
-
Electrochemistry
- Potentiostats & Galvanostats
-
Electrodes ( working, Reference, Counter )
- Working Electrode
- Counter electrodes
- Reference electrode
-
pH Electrodes
- pH electrode for soil sample
- pH electrode for aquariums
- pH electrode for seawater
- pH electrode for potable water
- pH electrode for ultrapure water
- pH electrode for low ionic activity
- pH electrode for meat
- pH electrode for beer
- pH electrode for glue
- pH electrode for colorings
- pH electrode for cosmetic
- pH electrode for leather
- pH electrode for creams
- pH electrode for detergent
- pH electrode for effluent
- pH electrode for galvanic effluent
- pH electrode for school and universities
- pH electrode for clinical laboratories
- pH electrode for laboratory in general
- pH electrode for pharmaceutical laboratories
- pH electrode for milk and dairy
- pH electrode for waterfull media
- pH electrode for honey
- pH electrode for micro volumes
- pH electrode for paper
- pH electrode for proteins
- pH electrode for redox
- pH electrode for cheese
- pH electrode for liquid soap
- pH electrode for solids
- pH electrode for semisolid
- pH electrode for alcoholic solutions
- pH electrode for visual and dense solutions
- pH electrode for inorganic solvents
- pH electrode for organic solvents
- pH electrode for fruit juice
- pH electrode for vegetable juice
- pH electrode for sulfates
- pH electrode for flat surfaces
- pH electrode for textile
- pH electrode for paintes
- pH electrode for titration
- pH electrode for wines
- RRDE / Polishing kit / Spectroeletrochemistry
- Voltametric cells & Flow cells
- Lithography / Glass substrate electrode
- Corrosion tests
- FANN Instrument ( ship only to Brazil )
- Impedance Analysers
- NIR
- CO2 & CH4 & Biogas and Hydrogen
-
Notas Técnicas em Eletroquímica
- Base del potenciostato
- Base del electrodo de trabajo
- Variedad, características y formas de los electrod
- Electrodo de referencia
- Contraelectrodo
- Voltametría hidrodinámica
- IDA electrodo
- Decapado Voltimétrico Cíclico (CVS)
- Cómo pulir la superficie de los electrodos de trab
- Datos experimentales del electrodo de hidrógeno re
- Electroforesis capilar
- Microchip de Electroforesis
- Cromatografía
- Procedimiento de limpieza y mantenimiento de eelec
- Procedimiento de calibración pH, ORP Condutividad
- ¿CÓMO PULIR EL CONJUNTO DE ANILLO PT DRE-PTR?
- Fuel cell Glossary
- Electrochemical Glossary
- Biblioteca de peliculas
- GLOSSÁRIO ELETROQUÍMICO
- Publications
- Allum News
- Technology of ACLN Nitrogen Liquefier
- Inicio
- > Electrochemistry
- > Electrodes ( working, Reference, Counter )
- > pH Electrodes
- > Electrodo de pH Semi-micro LabSen 241-6 (AI3103)
Electrodo de pH de combinación profesional LabSen® 241-6 para muestras pequeñas (> 0,2 ml), conector BNC
Descripción
- Tecnología y materiales patentados del sensor de pH de Suiza
- Punta de sensor cilíndrica semi-micro especial LabSen, adecuada para medición de pH de pequeño volumen (> 0,2 ml)
- Conector BNC
- Garantía de 6 meses cumplida por Apera Instruments
Respaldado por tecnología y materiales suizos de sensores de pH, el Electrodo de pH Semi-Micro LabSen 241-6 está diseñado para muestras de pequeño volumen (≥0.2 ml) .
Membrana de vidrio exclusiva : el electrodo de pH LabSen 241-6 adopta una membrana de vidrio semicilíndrica cilíndrica (6 mm de diámetro), lo que hace que las pruebas de pH de muestras pequeñas sean más fáciles que nunca y puede probarse en muestras de alta temperatura (hasta 212 ° F) .
Sistema de referencia Long-Life : compuesto por un tubo de vidrio, AgCl y un cable de plata de referencia. El extremo superior del delgado tubo de vidrio está relleno de algodón, lo que evita la reacción entre el AgCl y el electrolito cuando cambia la temperatura. Mejora la estabilidad del electrodo de referencia y prolonga la vida útil del electrodo.
El electrodo utiliza un conector BNC, compatible con cualquier medidor de pH que utilice conectores BNC, como Apera Instruments MP511 , SX811 , PH700 , PH800 , PC800 , PH820 y PC820 . El sensor de temperatura no está incorporado. Los usuarios deben tener una sonda de temperatura separada (por ejemplo, Apera Instruments MP500 ) para habilitar el ATC o la temperatura de entrada manual para realizar la compensación de temperatura.
El electrodo está respaldado por Apera Instruments con una garantía de 6 meses.
Aplicaciones
- Pequeñas-micro muestras
Especificaciones
N° Catálogo |
AI3103 |
|
Material |
Vidrio sin plomo |
|
Sensor de compensación de temperatura incorporado |
No |
|
Unión |
Cerámica |
|
Referencia |
Larga Vida |
|
Electrolito |
KCL 3M |
|
Longitud |
150 mm |
|
Diámetro |
12-6 mm |
|
Forma de la membrana |
Cilíndrica |
|
Rango |
0-14 pH |
|
Rango de Temperatura |
0 to 100˚C (32 to 212˚F) |
|
Conector |
BNC |
|
Cable |
3 ft |
Productos similares
Navegación
Contactanos
- +14073604114
- [email protected]
- 5605 International Dr Orlando FL 32819